| Rated capacities(Emax) | 10, 30, 35, 50Kg |
| Sensitivity | 2.0 mV/V ± 10% |
| Accuracy class | OIML C3 |
| Max No.of loadcell interval(nmax) | 3000 |
| Min No.of loadcell interval(Vmin) | Emax/7000 |
| Non-linearity | 0.017 %R.O. |
| Hysteresis | 0.017 %R.O. |
| 30min Creep | 0.017 %R.O. |
| 30mins Return | 0.017 %R.O. |
| Safe Overload | 150 %R.O. |
| Ultimate Overload | 200 %R.O. |
| Temperature Effect On Output | 0.0015 %R.O./℃ |
| Temperature Effect On Zero | 0.002 %R.O./℃ |
| Input Impedance | 410±15 Ω |
| Output Impedance | 350±5 Ω |
| Insulation Impedance | ≥5000 MΩ/(50VDC) |
| Recommended Excitation | 5~12 VDC |
| Maximum Excitation | 15 VDC |
| OperatingTemperatureRange | -20~60 ℃ |
| Construction | Aluminum Alloy |
| Protection Class | IP66 / IP67 |
| Cable | φ4×0.5m |
| Recommended Platform Size | 350×400 mm |
| Mode of Connection | Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-) |