Installation Feet

Rated Load (Kg)DLHB
100 – 750M125176.219.1
1000M125176.225.4
1200 – 1500M20x1.576.2100.431.8
Rated capacities(Emax)100,150,250, 500, 750Kg 1, 2, 3, 5t
Sensitivity3.0± 0.003mV/V
Accuracy classC2 – C5
Zero balance± 1% F.S.
TCO (Temperature Coefficient of Offset)± 0.02%F.S. /10°C
TC SPAN (Temperature Coefficient of Span)± 0.02%F.S. /10°C
Input impedance400 ± 20 Ω
Output impedance352 ± 3 Ω
Insulation impedance≥5000 MΩ
Temperature range, compensated-10°C ~ +40°C
Temperature range, operating-30°C ~ +70°C
Maximum safe overload120% F.S.
Ultimate overload150% F.F.
Excitation, recommend10V ~ 12V DC
Excitation maximum15V DC
Protection classIP65(100 ~ 1000Kg),IP68(1.2 ~ 5t)
ConstructionAlloy Steel or Stainless Steel
Cable diameter5mm, 4 core
Cable Length 5m